Dell

PowerConnect Switches

Description:

Check uptime, port status and environmental health on Dell PowerConnect switches. Global OIDs are used where possible for maximum compatibility across all models.

Current Version

1.5

Last Release Date

2016-06-09

Compatible With

  • Nagios 3.x
  • Nagios 4.x

License

GPL


Project Files
Project Notes
*** LATEST CHANGES: Split up "asset" check to only report Serial / Service Tag. New "description" check will return make & model. Also rewrote code to support SNMPv3 checking. Along with this came improved error handling and also use of passing user-friendly -- parameters. Finally, simplified output and and improved perfdata. This plugin attempts to get you as much information as needed out of your Dell switches. Usage for SNMP v1/2c: check_powerconnect -H {host/IP} -t {type of check} [-C {SNMP community}] [-p] [-w] [-c] [-S] Usage for SNMP v3: check_powerconnect -v 3 -H {host/IP} -t {type of check} -u {user} -x {protocol} -X {password} -a {protocol} -A {password} -l {security mode} [-p] [-S] [-w] [-c] Possible checks to run are as follows: assets description uptime ports port health temps fans psus So, to check the status of port 2: check_powerconnect -H {host/IP} -C {SNMP community} -t port -p 2 Or for ports 1, 3, 6 and 10: check_powerconnect -H {host/IP} -C {SNMP community} -t port -p 1,3,6,10 To check the status of the power supplies: check_powerconnect -H {hostname / IP address} -C {SNMP community} -t psus As the Dell manual for our PowerConnect specifies - 1 switch is treated as a "stack" , so interpret output appropriately. Although loss of *redundant* power is not typically critical, I have treated it as such to ensure you receive an e-mail (without having to tweak the plugin configuration).
Reviews (2) Add a Review
Feature proposal - warning on ports up (or down)
by jeremie.legrand, May 31, 2017

Hello, Thanks for your job. It would be great if we can trigger a warning when the number of active ports is under a specific value. For example, warning if only 7 ports are up, and critical if only 6 are up: ./check_powerconnect -H ip -C public -t ports -w 7 -c 6 Best regards, Jeremie L.



Need some changes
by raprop, June 30, 2012

Hi... im test the plugins and work, but require some changes, dont work with all switch dell. Im test with 35XX, 33XX, 80XX, 60XX, 62XX, 53XX, 54XX. assets work fine but some models dont return nothing, idem for temps, then scripts failed and show execution error. minor error code, but is a begin ^^