RAID Controllers

Dell OpenManage Storage

Description:

Checks storage devices (disks, RAIDs, controllers) attached to Dell server systems.

Current Version

Last Release Date

June 5, 2009

Compatible With


Project Files
Project Notes
Checks controllers, disks and RAID drives using the "omreport storage" command from Dell OpenManage. Tested with various plain SCSI and Perc3, Perc4, Perc5 and Perc6 RAID controllers (SATA/SCSI/SAS, internal and external storage). Tested in OpenManage 4.5, 5.0, 5.1, 5.2, 5.3, 5.4, 5.5 environments. Requires OpenManage 4.3 or later. Requires Perl. Supports sudo. New features: - more output in case of errors - detects driver and firmware version issues - fixed battery state recognition - evaluates connectors and enclosures as well - version-related warnings may be switched off
Reviews (1) Add a Review
Working
by nishith, August 31, 2012

Plugin worked well. Below is the output. ./check_om_storage.pl --analyze --CMD1 parsed output: OpenManage version: 5.5.0 --CMD2--: /usr/bin/omreport storage controller -fmt ssv Controller PERC 4e/Di Controllers --CMD2 results: Got 6 controller lines Checking Controller No. 0: PERC 4e/Di --CMD3--: /usr/bin/omreport storage pdisk controller=0 -fmt ssv List of Physical Disks on Controller PERC 4e/Di (Embedded) Controller PERC 4e/Di (Embedded) ID;Status;Name;State;Failure Predicted;Progress;Type;Capacity;Used RAID Disk Space;Available RAID Disk Space;Hot Spare;Vendor ID;Product ID;Revision;Serial No.;Negotiated Speed;Capable Speed;Manufacture Day;Manufacture Week;Manufacture Year;SAS Address 0:0;Ok;Physical Disk 0:0;Online;No;Not Applicable;SCSI;136.62 GB (146695782400 bytes);136.62 GB (146695782400 bytes);0.00 GB (0 bytes);No;MAXTOR ;ATLAS10K5_146SCA;JNZY;J408BN9K;320;320;Not Available;Not Available;Not Available;Not Available 0:1;Ok;Physical Disk 0:1;Online;No;Not Applicable;SCSI;136.62 GB (146695782400 bytes);136.62 GB (146695782400 bytes);0.00 GB (0 bytes);No;MAXTOR ;ATLAS10K5_146SCA;JNZY;J407W95K;320;320;Not Available;Not Available;Not Available;Not Available 0:2;Ok;Physical Disk 0:2;Online;No;Not Applicable;SCSI;136.62 GB (146695782400 bytes);136.62 GB (146695782400 bytes);0.00 GB (0 bytes);No;MAXTOR ;ATLAS10K5_146SCA;JNZY;J4081FLK;320;320;Not Available;Not Available;Not Available;Not Available 0:3;Ok;Physical Disk 0:3;Online;No;Not Applicable;SCSI;136.62 GB (146695782400 bytes);136.62 GB (146695782400 bytes);0.00 GB (0 bytes);No;MAXTOR ;ATLAS10K5_146SCA;JNZY;J4080E4K;320;320;Not Available;Not Available;Not Available;Not Available --CMD3 results: Got 9 physical disk lines on controller 0 --CMD4--: /usr/bin/omreport storage vdisk controller=0 -fmt ssv Virtual Disk 0 on Controller PERC 4e/Di (Embedded) Controller PERC 4e/Di (Embedded) ID;Status;Name;State;Progress;Layout;Size;Device Name;Type;Read Policy;Write Policy;Cache Policy;Stripe Element Size;Disk Cache Policy 0;Ok;Virtual Disk 0;Ready;Not Applicable;RAID-5;409.86 GB (440087347200 bytes);/dev/sda;SCSI;Adaptive Read Ahead;Write Back;Direct I/O;64 KB; --CMD4 results: Got 7 logical disk lines on controller 0 Status of physical disk 0:0: Ok, state: Online, predicted: No, progess: Not Applicable Status of physical disk 0:1: Ok, state: Online, predicted: No, progess: Not Applicable Status of physical disk 0:2: Ok, state: Online, predicted: No, progess: Not Applicable Status of physical disk 0:3: Ok, state: Online, predicted: No, progess: Not Applicable Status of virtual disk 0: Ok, state: Ready, progress: Not Applicable, type: RAID-5 Checking Enclosures on Controller 0: --CMD5--: /usr/bin/omreport storage enclosure controller=0 -fmt ssv Enclosure(s) on Controller PERC 4e/Di (Embedded) ID;Status;Name;State;Connector ;Target ID;Configuration;Firmware Version;Service Tag;Asset Tag;Asset Name;Backplane Part Number;Split Bus Part Number;Enclosure Part Number;SAS Address;Enclosure Alarm 0;Ok;Backplane;Ready;0;6;Not Applicable;1.0 ;61900ER;Not Applicable;Not Applicable;Not Applicable;Not Applicable;Not Applicable;Not Applicable;Not Applicable --CMD5 results: Got 5 enclosure lines Status of enclosure 0 (Backplane): Ok, state: Ready Checking Connectors on Controller 0: --CMD6--: /usr/bin/omreport storage connector controller=0 -fmt ssv List of Connector(s) on Controller PERC 4e/Di (Embedded) ID;Status;Name;State;Connector Type;Termination;SCSI Rate 0;Ok;Connector 0;Ready;SCSI Channel RAID Mode;Wide Terminated;Ultra 320M SCSI 1;Ok;Connector 1;Ready;SCSI Channel RAID Mode;Wide Terminated;Ultra 320M SCSI --CMD6 results: Got 5 connector lines Status of connector 0 (Connector 0, SCSI Channel RAID Mode): Ok, state: Ready Status of connector 1 (Connector 1, SCSI Channel RAID Mode): Ok, state: Ready Checking Batteries on Controller 0: --CMD7--: /usr/bin/omreport storage battery controller=0 -fmt ssv Battery 0 on Controller PERC 4e/Di (Embedded) Controller PERC 4e/Di (Slot Embedded) ID;Status;Name;State;Recharge Count;Max Recharge Count;Predicted Capacity Status;Learn State;Next Learn Time;Maximum Learn Delay 0;Ok;Battery 0;Ready;1;1100;Not Applicable;Not Applicable;Not Applicable;Not Applicable --CMD7 results: Got 6 battery lines Status of battery 0: Ok, state: Ready Result: 0 STORAGE: OK [ Ctrl 0 (PERC 4e/Di is Non-Critical (Degraded: firmware mismatch: running: 521S, required: 522D)) ]



Add a Review

You must be logged in to submit a review.

Thank you for your review!

Your review has been submitted and is pending approval.

Recommend

To:


From:


Thank you for your recommendation!

Your recommendation has been sent.

Project Stats
Rating
4.3 (3)
Favorites
0
Views
105,041