HP (Compaq)
check_esxcli_hparray
Description:
A Nagios plugin that checks HP Proliant hardware raid via the VMWare ESXCLI tool on ESXi servers with the HP Util Blunde installed (hpacucli namespace enabled).
This is based on the check_hparray plugin but with the checking order corrected in order to avoid false positives.
Current Version
0.9
Last Release Date
November 27, 2012
Compatible With
- Nagios 3.x
Owner
License
GPL
Project Files
File | Description |
---|---|
check_esxcli_hparray |
Project Notes
Reviews
(1)
Add a Review
VMware-vSphere-Perl-SDK must be installed at first on the Nagios system and
hp-HPutil package must be installed on the target esxi host, for example for esxi5.5: hp-HPUtil-esxi5.5-bundle-1.6-25.zip. And with this patch it will use the up-to-date command line utility and the message about a failed massive will be much more informative:
--- check_esxcli_hparray.sh 2015-02-10 16:35:14.000000000 +0300
+++ check_esxcli_hparray_new.sh 2015-02-16 13:17:53.667530088 +0300
@@ -102,12 +102,12 @@
echo "RAID OK - ($msg_ok)"
exit $exit_status
elif [ $exit_status -eq "1" ]; then
- msg_warning=`echo $check|grep -i rebuild`
+ msg_warning=`echo $check|grep -i rebuild|sed 's/.*Smart (.*)$/Smart 1/g'`
echo "RAID WARNING - ($msg_warning)"
exit $exit_status
elif [ $exit_status -eq "2" ]; then
- msg_critical1=`echo $check|grep -i failed`
- msg_critical2=`echo $check|grep -i recovery`
+ msg_critical1=`echo $check|grep -i failed|sed 's/.*Smart (.*)$/Smart 1/g'`
+ msg_critical2=`echo $check|grep -i recovery|sed 's/.*Smart (.*)$/Smart 1/g'`
echo "RAID CRITICAL - ($msg_critical1 $msg_critical2)"
exit $exit_status
fi
@@ -128,7 +128,7 @@
exit 0
;;
-h)
- check=`$ESXCLI -s $2 -u $4 -p $6 hpacucli cmd -q "controller slot=$8 ld all show"`
+ check=`$ESXCLI -s $2 -u $4 -p $6 hpssacli cmd -q "controller slot=$8 ld all show"`
check_raid
;;
*)