Build precise queries to find exactly what you need
Press ESC to close
Join our next live webinar: “Advanced Nagios Monitoring Techniques” – Register Now
Your review has been submitted and is pending approval.
Check performance, status, failover, hardware and other metrics on a F5 Load Balancer.
Perl script; requires Net::SNMP to work; Data::Dumper also needed if using the caching mode.
Use check_f5.pl -h for full syntax and usage.
Version 0.2 corrects an issue with Perl 5.10 support.
Current Version
0.2
Last Release Date
2012-11-19
Owner
Steve Shipway
License
GPL
Compatible With
Version 0.1
Version 0.2
Usage: ./check_f5.pl -H host [-C community] [-d][-h][-M][-t timout] [--no-perf] [--no-optimise] [-f cachefile] [-x cacheexpiretime] [-m modules] -H --host : Specify F5 hostname (f5) Can be used multiple times; the first to answer is used. -C --community : Specify SNMP community string (public) -d --debug : Debug mode. Use multiple times for more detail -h --help : Show help -M --mrtg : MRTG mode. Also --no-mrtg for Nagios mode. -t --timeout : SNMP query timeout (10) -f --cache-file : File basename for SNMP cache (/tmp/f5.cache) -x --cache-expire : Seconds before cache becomes invalid (290) --no-perf : Disable perfstats in Nagios output --no-optimise : Retrieve entire SNMP tree for tables (use in conjunction with cache if many separate server() checks being done) -m --modules : List modules to enable. Space separated. Can be used multiple times if required. See below. MRTG mode In MRTG mode, only the first module to provide a metric will be output. Available modules: cpu[:n][(warnpc,critpc)] MRTG: user and idle percent (80,90) mem[ory][:percent][(warnpc,critpc)] MRTG: used and total bytes (or %) (80,90) temp[erature][(warn,crit)] fan No MRTG output psu No MRTG output health Same as 'cpu mem temp fan psu' ssl[:server][(activewarn,activecrit)] MRTG: active and total SSL (500,400) traffic[:server] MRTG: bytes in/out. No Nagios. server:name[(actvw,actvc)] For virt server name (500,400) server:ipaddr[:port][(actvw,actvc)] For virt server ipaddr:port server[(actvw,actvc)] Over ALL virtual servers (50000,40000) cert[ificate][:certname][([warn,]crit)] Check certificate days left, no MRTG conn[ections][(actvw,actvc)] same as 'server' group Failover health. No MRTG output. cm Same as 'group' cache No output; prepare SNMP cache Server checks: For server checks, the number of active connections will be thresholded. Next, the availability of the Server will be checked and will return WARN if not all the active pool members are available. Examples: ./check_f5.pl -H myf5 -C public -m 'cpu(80,90) server:/Production/foobar' ./check_f5.pl -H myf5 -m 'health certificates(14,7) conn(1500,2000)'
This is the best plugin I've tested so far. Very flexible. Includes PerfData. Results are consistent w/ F5's Admin GUI!
Thank you for this plugin. I've implemented it against a BigIP 3900 with version 10.2.3 Build 123.0 Hotfix HF1. Using 0.2 CPU, Mem, Conn/Server, and Group modules all work nicely. However Cert returns "Cannot determine expiry date for " Also for Server: check, I execute ./check_f5 -H mylb -C mycommunity -m 'server:/Production/virtualservername' and get "/Production/virtualservername: Not enable (noSuchInstance)" Perhaps I am not understanding something.
Hi, Im getting an error when executing this plugin: ./check_f5.pl Not enough arguments for unpack at ./check_f5.pl line 159, near "'C' }" Execution of ./check_f5.pl aborted due to compilation errors. Even if i added the hostname, community string and modules, its still the same error. Can you help me identify whats causing this. Thanks
Looks promising. Haven't been able to test this very much since I'm on very old 9.x for the most which gives: Illegal division by zero at /opt/nagios/libexec/check_f5.pl line 619. For v.10 and 1500 box it gives some issues around fans which I believe is incorrect. Also, default temperature thresholds might be a bit low. snmpwalk -v2c test -c test .1.3.6.1.4.1.3375.2.1.3 -m all F5-BIGIP-SYSTEM-MIB::sysCpuNumber.0 = INTEGER: 1 F5-BIGIP-SYSTEM-MIB::sysCpuIndex.1 = INTEGER: 1 F5-BIGIP-SYSTEM-MIB::sysCpuTemperature.1 = INTEGER: 43 F5-BIGIP-SYSTEM-MIB::sysCpuFanSpeed.1 = INTEGER: 6420 F5-BIGIP-SYSTEM-MIB::sysCpuEntry.4.1 = STRING: "cpu1" F5-BIGIP-SYSTEM-MIB::sysCpuEntry.5.1 = INTEGER: 0 F5-BIGIP-SYSTEM-MIB::sysChassisFanNumber.0 = INTEGER: 6 F5-BIGIP-SYSTEM-MIB::sysChassisFanIndex.101 = INTEGER: 101 F5-BIGIP-SYSTEM-MIB::sysChassisFanIndex.102 = INTEGER: 102 F5-BIGIP-SYSTEM-MIB::sysChassisFanIndex.103 = INTEGER: 103 F5-BIGIP-SYSTEM-MIB::sysChassisFanIndex.104 = INTEGER: 104 F5-BIGIP-SYSTEM-MIB::sysChassisFanIndex.105 = INTEGER: 105 F5-BIGIP-SYSTEM-MIB::sysChassisFanIndex.106 = INTEGER: 106 F5-BIGIP-SYSTEM-MIB::sysChassisFanStatus.101 = INTEGER: good(1) F5-BIGIP-SYSTEM-MIB::sysChassisFanStatus.102 = INTEGER: good(1) F5-BIGIP-SYSTEM-MIB::sysChassisFanStatus.103 = INTEGER: good(1) F5-BIGIP-SYSTEM-MIB::sysChassisFanStatus.104 = INTEGER: good(1) F5-BIGIP-SYSTEM-MIB::sysChassisFanStatus.105 = INTEGER: good(1) F5-BIGIP-SYSTEM-MIB::sysChassisFanStatus.106 = INTEGER: good(1) F5-BIGIP-SYSTEM-MIB::sysChassisFanSpeed.101 = INTEGER: 9926 F5-BIGIP-SYSTEM-MIB::sysChassisFanSpeed.102 = INTEGER: 9926 F5-BIGIP-SYSTEM-MIB::sysChassisFanSpeed.103 = INTEGER: 9926 F5-BIGIP-SYSTEM-MIB::sysChassisFanSpeed.104 = INTEGER: 9782 F5-BIGIP-SYSTEM-MIB::sysChassisFanSpeed.105 = INTEGER: 9642 F5-BIGIP-SYSTEM-MIB::sysChassisFanSpeed.106 = INTEGER: 9926 F5-BIGIP-SYSTEM-MIB::sysChassisPowerSupplyNumber.0 = INTEGER: 1 F5-BIGIP-SYSTEM-MIB::sysChassisPowerSupplyIndex.101 = INTEGER: 101 F5-BIGIP-SYSTEM-MIB::sysChassisPowerSupplyStatus.101 = INTEGER: good(1) F5-BIGIP-SYSTEM-MIB::sysChassisTempNumber.0 = INTEGER: 2 F5-BIGIP-SYSTEM-MIB::sysChassisTempIndex.1 = INTEGER: 1 F5-BIGIP-SYSTEM-MIB::sysChassisTempIndex.101 = INTEGER: 101 F5-BIGIP-SYSTEM-MIB::sysChassisTempTemperature.1 = INTEGER: 41 F5-BIGIP-SYSTEM-MIB::sysChassisTempTemperature.101 = INTEGER: 36 F5-BIGIP-SYSTEM-MIB::sysGeneralHwName.0 = STRING: C36 F5-BIGIP-SYSTEM-MIB::sysGeneralHwNumber.0 = STRING: deprecated F5-BIGIP-SYSTEM-MIB::sysGeneralChassisSerialNum.0 = STRING: bip256156s F5-BIGIP-SYSTEM-MIB::sysPlatform.5.1.0 = STRING: "C36" F5-BIGIP-SYSTEM-MIB::sysPlatform.5.2.0 = STRING: "BIG-IP 1500" ./check_f5.pl -H test -C test Checks FAILED. See details.|cpu_user=9%;80;90;0;100 cpu_idle=85%;20;10;0;100 mem_pc=1.77%;80;90;0;100 mem_used=26110896;1179438284;1326868070;0;1474297856 CPU average usage: 9% (idle 85%) Memory usage 1.77% Temperature sensor #2 has unknown status. CRIT: Temp sensor #1 reads 41 >= 35 Unit fan #6 has failed. Unit fan #5 has failed. Unit fan #4 has failed. Unit fan #3 has failed. Unit fan #2 has failed. Unit fan #1 has failed. Unit PSU #1 has failed.
You must be logged in to submit a review.