RAID Controllers

Check Dell PERC Array

Description:

Using Net::SNMP, this script checks the channel state, global state and disk states of a PERC RAID array on a server running Dell’s OpenManage

Current Version

Last Release Date

June 5, 2009

Compatible With


Project Files
Project Notes
Requires Net::SNMP Perl Module on the Nagios server. Requires Dell OpenManage software to be running on the target server. Checks the global status of the "Storage" section in OpenManage. Checks the status of the controller channel. And finally loops through all of the disks in the array and reports their status. Update includes extra logic for PERC battery's that are constantly recharging, reports a warning in stead of critical.
Reviews (1) Add a Review
little fix
by bva, September 30, 2011

A little fix to force return of WARNING if GlobalState report only a WARNING. @@ -322,9 +322,9 @@ if ($GlobalState[1] ne 'NORMAL') { - if ($GlobalState[1] eq 'WARNING') + if ($GlobalState[3] eq 'OK') { - $WorstState = 'WARNING'; + $WorstState = 'CRITICAL'; } # Battery State Check elsif ((($GlobalState[3] eq 'RECONDITIONING') || ($GlobalState[3] eq 'CHARGING') || ($GlobalState[3] eq 'LOW')) && ($GlobalState[1] ne 'CRITICAL'))



Add a Review

You must be logged in to submit a review.

Thank you for your review!

Your review has been submitted and is pending approval.

Recommend

To:


From:


Thank you for your recommendation!

Your recommendation has been sent.

Project Stats
Rating
4.3 (3)
Favorites
2
Views
111,521