TOP LEVEL CATEGORIES
EXPLORE
Description:
This plugin checks the status of objects monitored by Dell OpenManage via SNMP and returns OK, WARNING, CRITICAL or UNKNOWN. If a failure occurs it will describe the subsystem that failed and the failure code.
As featured in Linux Journal issue 182 http://www.linuxjournal.com/issue/182
Current Version
1.3
Last Release Date
2010-02-31
Compatible With
Owner
Jason Ellison
Website
http://www.jasonellison.net/projects.html
check_dell_openmanage.1.3.pl
MIBs for Dell PowerEdge servers
Shell script used to emulate a Dell OpenManage agent for testing
INFORMATION ABOUT THIS PLUGIN
This plugin checks the status of objects monitored by Dell OpenManage via SNMP and returns OK, WARNING, CRITICAL or UNKNOWN. If not OK it returns text describing which subsystem failed. This plugin focuses on low bandwidth and speed. Questions, comments and criticisms are appreciated.
This program is written and maintained by: Jason Ellison - infotek(at)gmail.com http://www.jasonellison.net/
t is based on check_snmp_temperature.pl plugin by: William Leibzon - william(at)leibzon.org
-= SETUP NOTES =-
Copy this file to your Nagios installation folder in "libexec/". Rename to "check_dell_openmanage.pl".
You must have Dell OpenManage installed on the server you wish to monitor. You must have enabled SNMP on the server and allow SNMP queries. On the nagios server that will be running the plugin you must have the perl "Net::SNMP" module installed.
perl -MCPAN -e shell cpan> install Net::SNMP
Check Dell OpenManage locally on the monitored host for alert threshholds like min/max fan speeds...
To do a test run using SNMPv1 try:
./check_dell_openmanage.pl -H 192.168.1.250 -C public -T test
This will report which OID's your system supports.
-= OIDS Checked by System Type=-
System Types
"dellom" monitors the following OID's:
systemStateChassisStatus .1.3.6.1.4.1.674.10892.1.200.10.1.4.1 systemStatePowerSupplyStatusCombined .1.3.6.1.4.1.674.10892.1.200.10.1.9.1 systemStateVoltageStatusCombined .1.3.6.1.4.1.674.10892.1.200.10.1.12.1 systemStateCoolingDeviceStatusCombined .1.3.6.1.4.1.674.10892.1.200.10.1.21.1 systemStateTemperatureStatusCombined .1.3.6.1.4.1.674.10892.1.200.10.1.24.1 systemStateMemoryDeviceStatusCombined .1.3.6.1.4.1.674.10892.1.200.10.1.27.1 systemStateChassisIntrusionStatusCombined .1.3.6.1.4.1.674.10892.1.200.10.1.30.1 systemStateEventLogStatus .1.3.6.1.4.1.674.10892.1.200.10.1.41.1
"dellom_storage" test all of the OID's "dellom" tests plus the storage OID
systemStateChassisStatus .1.3.6.1.4.1.674.10892.1.200.10.1.4.1 systemStatePowerSupplyStatusCombined .1.3.6.1.4.1.674.10892.1.200.10.1.9.1 systemStateVoltageStatusCombined .1.3.6.1.4.1.674.10892.1.200.10.1.12.1 systemStateCoolingDeviceStatusCombined .1.3.6.1.4.1.674.10892.1.200.10.1.21.1 systemStateTemperatureStatusCombined .1.3.6.1.4.1.674.10892.1.200.10.1.24.1 systemStateMemoryDeviceStatusCombined .1.3.6.1.4.1.674.10892.1.200.10.1.27.1 systemStateChassisIntrusionStatusCombined .1.3.6.1.4.1.674.10892.1.200.10.1.30.1 systemStateEventLogStatus .1.3.6.1.4.1.674.10892.1.200.10.1.41.1 StorageManagement-MIB::agentGlobalSystemStatus .1.3.6.1.4.1.674.10893.1.20.110.13.0
"blade"
systemStateChassisStatus .1.3.6.1.4.1.674.10892.1.200.10.1.4.1 systemStateVoltageStatusCombined .1.3.6.1.4.1.674.10892.1.200.10.1.12.1 systemStateTemperatureStatusCombined .1.3.6.1.4.1.674.10892.1.200.10.1.24.1 systemStateMemoryDeviceStatusCombined .1.3.6.1.4.1.674.10892.1.200.10.1.27.1 systemStateEventLogStatus .1.3.6.1.4.1.674.10892.1.200.10.1.41.1 StorageManagement-MIB::agentGlobalSystemStatus .1.3.6.1.4.1.674.10893.1.20.110.13.0
"global" monitors
GlobalSystemStatus .1.3.6.1.4.1.674.10892.1.200.10.1.2.1
"chassis" monitors
ChassisStatus .1.3.6.1.4.1.674.10892.1.200.10.1.4.1
"custom" is meant to be customised by advanced users
-= TODO =-
* Fix bugs and make more user friendly.
-= REVISION =-
ver 1.3 * If non-numeric codes are returned just add the text to the statusinfo * This was done to allow adding machine information Dell Model Number and Service Tag to output. ver 1.2 *major rewrite. simplified the way new systems are defined. *added system type "test" which can be used to easly generate new system definitions. ver 1.1 *formating of text output *add blade system type... blades apparently do not support systemStatePowerSupplyStatusCombined, systemStateCoolingDeviceStatusCombined or systemStateChassisIntrusionStatusCombined ver 1.0 *while in verbose mode report which OID failed in a more readable manner. *add "global", "chassis", and "custom" system type. *removed system type pe2950. ver 0.9 *added type dellom_storage as this is more accurate. this plugin works with all PowerEdge servers it has been tested with. left pe2950 type in for compatibility. *remove min max int options from help text as they are no longer relevant ver 0.8 *check that perl environment has "Net::SNMP" if not found complain. missing "Net::SNMP" is the most common issue users report. ver 0.7 *removed ucdavis definition. Added note about SNMPv3 dependencies
Dell OpenManage Server Administrator Version 5.4 SNMP Reference Guide
http://support.dell.com/support/edocs/software/svradmin/5.4/en/snmp/pdf/om_54_snmp_ref_gd.pdf
Dell OpenManage Server Administrator Version 1.0 to 6.2 SNMP Reference Guide
http://support.dell.com/support/edocs/software/svradmin/6.3/en/SNMP/1.0-6.2/PDF/SNMP.pdf
Preparing the Dell Openmange server for monitoring:
Linux: http://www.ubergeek.co.uk/blog/2008/05/dell-openmanage-on-linux-debian/
Windows: http://docs.google.com/View?docID=dg2fzp3d_4d2pgb3cp
You must be logged in to submit a review.
Your review has been submitted and is pending approval.
To:
From:
Your recommendation has been sent.